orjoLC-1 Loudness Correction
Specs / North America / TV commercials

USA commercial TV loudness spec

What a file has to measure to pass this spec, and where each figure comes from.

CheckRequiredIn LC-1
Integrated loudness−24.0 ±2 LKFSFixed with a level change
True peak−2.0 dBTP maxLimited, with audition
Format48 kHzFlagged

Worth knowing

A/85 says not to aim at either edge of the ±2 window. XR recommends keeping true peak under −6 dBTP to avoid rejections.

Data source(s)

  • ATSC A/85:2026-07 (the FCC’s CALM Act rules cite A/85:2013)
  • XR North America spec

Figures taken from the documents above and last read on 10 October 2026.

Something incorrect with this spec? Report it to support@orjo.co.uk.