What a file has to measure to pass this spec, and where each figure comes from.

CheckRequiredIn LC-1
Integrated loudness−23.0 ±0.2 LUFSFixed with a level change
True peak−1.0 dBTP maxLimited, with audition

Worth knowing

The ±0.2 LU is the measurement tolerance R128 allows in quality control. Live content is allowed ±1.0 LU.

Data source(s)

  • EBU R 128 v5, November 2023

Figures taken from the documents above and last read on 10 October 2026.