What a file has to measure to pass this spec, and where each figure comes from.

CheckRequiredIn LC-1
Integrated loudness−23.0 ±0.0 LUFSFixed with a level change
True peak−3.0 dBTP maxLimited, with audition
Max short-term−20.0 LUFSFlagged
Format48 kHz, 24-bit PCMFlagged

Worth knowing

In France −23 LUFS is a maximum for adverts and XR allows no tolerance, so the file is set to −23.0.

Data source(s)

  • CSA (now Arcom) deliberation 2011-29
  • XR France spec
  • Cape France spec (CST RT-040)

Figures taken from the documents above and last read on 10 October 2026.